The Polaris platform was created by Sensyne Health Ltd., and has now been made open-source. As a result, some of the instructions, setup and configuration will no longer be relevant to third party contributors. For example, some of the libraries used may not be publicly available, or docker images may not be accessible externally. In addition, CICD pipelines may no longer function.

For now, Sensyne Health Ltd. and its employees are the maintainers of this repository.

Overview

Python's logging is initialised to produce JSON format log records (override with LOG_FORMAT environment) and the log level is set to INFO (override using LOG_LEVEL environment)

Environment variable Description
LOG_LEVEL Sets log level for the root logger. Default INFO, other values DEBUG, WARNING, ERROR
LOG_FORMAT Default json, other values plain, colour or color
LOG_LEVEL_CONNEXION Default INFO
LOG_LEVEL_NEOBOLT Default INFO
LOG_LEVEL_NEO4J Default WARNING
LOG_LEVEL_OPENAPI_SPEC_VALIDATOR Default INFO
LOG_LEVEL_PIKA Default INFO
LOG_LEVEL_GUNICORN Default INFO
LOG_LEVEL_UVICORN Default INFO
LOG_LEVEL_UVICORN_ACCESS Default INFO
LOG_LEVEL_UVICORN_ERROR Default INFO
LOG_LOCALS Default True, when LOG_FORMAT=colour includes local variables in stack traces. Set to False to disable.
COLUMNS when LOG_FORMAT=colour it sets the width of logging output. Default is the width fo the console window. Use this with colour logging in a docker container where the width cannot be detected automatically.

Colour logging

To enable colour logging install she-logging with extras=colour to add rich as a dependency, or just ensure you install rich.

Logs will be colour when the output device is detected as a terminal (otherwise monochrome). Tracebacks in this mode are enhanced to include context and optionally local variables.

The coloured logs show times to one second accuracy and for clarity omit duplicated times.

Use

For simple cases just import and use the logger. Logging is initialised when the first log message is output:

from time import sleep

from she_logging import logger

def foo(x:int, y:int) -> float:
    return x/y

logger.info('Hello world')
logger.debug("Debug message", extra={"data": {"hello": 1, "world": 42}})
sleep(1)
try:
    foo(1, 0)
except ZeroDivisionError as e:
    logger.exception('It blew up')

Interactive example

Uvicorn Logging

Uvicorn is best started using a python script, pass it SHE_LOGGING_CONFIG for its logging configuration. She-logging does not need to be initialised separately.

import uvicorn

from she_logging import SHE_LOGGING_CONFIG

if __name__ == "__main__":
    uvicorn.run("tests.scripts.fastapi_app:app", host="127.0.0.1", port=8000, log_config=SHE_LOGGING_CONFIG, workers=3)
$ python tests/scripts/uvicorn-main.py

Example using uvicorn

Gunicorn Logging

Gunicorn accepts a logger class as a command line option. This is the preferred way to use it with she-logging as simply initialising she_logging within the app will result in gunicorn's own messages being formatted incorrectly.

Either of these commands will have the desired effect:

gunicorn --logger-class egg:she_logging#gunicorn tests.scripts.flask_app:app
gunicorn --logger-class she_logging.gunicorn_logger.Logger tests.scripts.flask_app:app

Example using gunicorn

Gunicorn + Uvicorn

The recommended configuration for production is to run uvicorn under gunicorn. This can be done simply by including the logger-class for gunicorn and uvicorn will use the correct logger. N.B. To use gunicorn and uvicorn together in this way you must also install uvtools and httptools.

$ gunicorn --logger-class she_logging.gunicorn_logger.Logger tests.scripts.fastapi_app:app -w 4 -k uvicorn.workers.UvicornWorker

Example using gunicorn to run uvicorn

init_logging()

When used within a framework it may be useful to initialise logging explicitly by calling init_logging(). This function may also be used to override the log configuration:

from she_logging.logging import init_logging, SHE_LOGGING_CONFIG

init_logging() # Uses default configuration
# or
init_logging(config=SHE_LOGGING_CONFIG)
# or
init_logging(config="log_config.yaml")

Any calls to init_logging() after logging has been initialised by another package will use the SHE logging configuration for new loggers. Existing loggers will continue to work but may not use the correct handler.

init_logging() takes an optional configuration as a dict, a JSON or Yaml filename, or the yaml of the configuration.

Sample logging configuration:

formatters:
  json:
    (): "she_logging.logging.CustomisedJSONFormatter"
  simple:
    format: '[%(asctime)s] %(levelname)s [%(requestID)s] in %(module)s:%(lineno)s: %(message)s'
handlers:
  json:
    class: logging.StreamHandler
    formatter: json
    stream: ext://sys.stdout
  plaintext:
    class: logging.StreamHandler
    formatter: simple
    stream: ext://sys.stdout
loggers:
  uvicorn:
    level: INFO
  uvicorn.access:
    level: INFO
    propagate: false
  uvicorn.error:
    level: INFO
root:
  handlers:
  - json
  level: DEBUG
version: 1

Installation

Clone the repo, enter the newly created directory

Build and activate a virtualenv using the make install command:

make install

Running the Unit Tests

Tests can be run using pytest or tox - it's up to you. The make command uses tox but py.test runs faster.

make test

The default make test or tox targets test using both Python 3.9 and Python 3.6. You should ensure both are available if you use these tests. To make alternative Pythons available in a pyenv environment you can add them to the pyenv local configuration (but you must already have installed the correct version(s)):

$ make pyenv
$ pyenv local she-logging 3.6.12

The tests should also pass using Python 3.9 but that is not verified by the automated testing.

You can also run them using the standard commands:

# run all
pytest

Running the Circle CI Unit Test Workflow

This is the unit & integration tests, coverage reports and linters (black, safety, isort etc.) and ran by Tox

make circleci-test

Running Coverage

Coverage should be 100%. To run the coverage report alone:

make test-coverage

Releasees

See https://sensynehealth.atlassian.net/wiki/spaces/SENS/pages/87588957/Library+releases

Please maintain up to date GitHub releases with every she_logging release.

Thank you.

Releases

No releases published

Packages

No packages published