Introduce feature which restricts the minimum global hsfll frequency. This feature is selected by default to preserve the behavior of the global hsfll before the clock control driver for it was introduced, which configured it as a fixed clock at 320MHz. Upstream PR #: 81735 Signed-off-by: Bjarki Arge Andreasen <[email protected]>
- Loading branch information
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,64 @@ | ||
/* | ||
* Copyright (c) 2024 Nordic Semiconductor ASA | ||
* | ||
* SPDX-License-Identifier: Apache-2.0 | ||
*/ | ||
|
||
#include <zephyr/drivers/clock_control/nrf_clock_control.h> | ||
#include <zephyr/kernel.h> | ||
#include <zephyr/logging/log.h> | ||
|
||
LOG_MODULE_DECLARE(soc, CONFIG_SOC_LOG_LEVEL); | ||
|
||
#if CONFIG_SOC_NRF54H20_GLOBAL_HSFLL_MIN_FREQ_64_MHZ | ||
#define GLOBAL_HSFLL_MIN_FREQ_HZ 64000000 | ||
#elif CONFIG_SOC_NRF54H20_GLOBAL_HSFLL_MIN_FREQ_128_MHZ | ||
#define GLOBAL_HSFLL_MIN_FREQ_HZ 128000000 | ||
#elif CONFIG_SOC_NRF54H20_GLOBAL_HSFLL_MIN_FREQ_256_MHZ | ||
#define GLOBAL_HSFLL_MIN_FREQ_HZ 256000000 | ||
#else | ||
#define GLOBAL_HSFLL_MIN_FREQ_HZ 320000000 | ||
#endif | ||
|
||
#define GLOBAL_HSFLL_REQUEST_TIMEOUT_US \ | ||
(CONFIG_SOC_NRF54H20_GLOBAL_HSFLL_TIMEOUT_MS * USEC_PER_SEC) | ||
|
||
Check notice on line 25 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
Check notice on line 25 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
Check notice on line 25 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
Check notice on line 25 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
|
||
static struct onoff_client cli; | ||
static const struct device *global_hsfll = DEVICE_DT_GET(DT_NODELABEL(hsfll120)); | ||
static const struct nrf_clock_spec spec = { | ||
.frequency = GLOBAL_HSFLL_MIN_FREQ_HZ, | ||
}; | ||
|
||
static int nordicsemi_nrf54h_global_hsfll_init(void) | ||
{ | ||
int ret; | ||
int res; | ||
bool completed; | ||
|
||
sys_notify_init_spinwait(&cli.notify); | ||
|
||
ret = nrf_clock_control_request(global_hsfll, &spec, &cli); | ||
if (ret) { | ||
return ret; | ||
} | ||
|
||
res = -EIO; | ||
completed = WAIT_FOR(sys_notify_fetch_result(&cli.notify, &res) == 0, | ||
GLOBAL_HSFLL_REQUEST_TIMEOUT_US, | ||
k_msleep(1)); | ||
|
||
Check notice on line 49 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
Check notice on line 49 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
Check notice on line 49 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
Check notice on line 49 in soc/nordic/nrf54h/global_hsfll.c GitHub Actions / Run compliance checks on patch series (PR)You may want to run clang-format on this change
|
||
if (!completed) { | ||
LOG_ERR("%s request timed out", "Restrict global HSFLL"); | ||
return -EIO; | ||
} | ||
|
||
if (res) { | ||
LOG_ERR("%s request failed: (res=%i)", "Restrict global HSFLL", res); | ||
return res; | ||
} | ||
|
||
LOG_INF("%s to %uHz", "Restrict global HSFLL", GLOBAL_HSFLL_MIN_FREQ_HZ); | ||
return 0; | ||
} | ||
|
||
SYS_INIT(nordicsemi_nrf54h_global_hsfll_init, POST_KERNEL, 99); |