Breaking change

This PR doesn't not introduce a breaking change

Proposed change

Currently you can configure the minium and maximum target temperatures if you create a generic thermostat in YAML. If you create it via the UI, there is no option to configure them, you just get the climate domain defaults.

This commit adds minimum and maximum fields to the first stage of the generic thermostat config flow, so that UI users can also set min and max.

Min and max are important as usually users want to select target temperatures within a relatively narrow band, while the defaults create a wide band. The wide band makes it hard to be accurate enough with the arc style temperatue selector on the thermostat card.

Type of change

  • Dependency upgrade
  • Bugfix (non-breaking change which fixes an issue)
  • New integration (thank you!)
  • New feature (which adds functionality to an existing integration)
  • Deprecation (breaking change to happen in the future)
  • Breaking change (fix/feature causing existing functionality to break)
  • Code quality improvements to existing code or addition of tests

Additional information

  • This PR fixes or closes issue: fixes #
  • This PR is related to issue:
  • Link to documentation pull request:

Checklist

  • The code change is tested and works locally.
  • Local tests pass. Your PR cannot be merged unless tests pass
  • There is no commented out code in this PR.
  • I have followed the development checklist
  • I have followed the perfect PR recommendations
  • The code has been formatted using Ruff (ruff format homeassistant tests)
  • Tests have been added to verify that the new code works.

If user exposed functionality or configuration variables are added/changed:

If the code communicates with devices, web services, or third-party tools:

  • The manifest file has all fields filled out correctly.
    Updated and included derived files by running: python3 -m script.hassfest.
  • New or updated dependencies have been added to requirements_all.txt.
    Updated by running python3 -m script.gen_requirements_all.
  • For the updated dependencies - a link to the changelog, or at minimum a diff between library versions is added to the PR description.

To help with the load of incoming pull requests:

  1. Add PARALLEL_UPDATES = 0 to Reolink platforms #131165 (review)
  2. Fix calendar translation strings #131160 (review)

Currently you can configure the minium and maximum target temperatures
if you create a generic thermostat in YAML. If you create it via the
UI, there is no option to configure them, you just get the climate
domain defaults.

This commit adds minimum and maximum fields to the first stage of the
generic thermostat config flow, so that UI users can also set min and
max.

Min and max are important as usually users want to select target
temperatures within a relatively narrow band, while the defaults create
a wide band. The wide band makes it hard to be accurate enough with the
arc style temperatue selector on the thermostat card.
@hughsaunders hughsaunders marked this pull request as ready for review November 21, 2024 16:51