Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Bulk Read Coils Limit #60

Open
MatthewHink opened this issue Aug 11, 2020 · 0 comments
Open

Bulk Read Coils Limit #60

MatthewHink opened this issue Aug 11, 2020 · 0 comments

Comments

@MatthewHink
Copy link
Contributor

Nice to have. Not currently a requirement.

The maximum number of holding registers or input registers that can be read on a bulk read network round trip is 123. Currently so too with coils.

The maximum amount of coils should be 123 * 16 = 1968.

This ticket is to change that limit to 1968, assuming the modbus library handles it.